+1-555-0202 hello@minimalin-demo.local

Export packing on qualified OEM orders.

Product

Ingersoll Rand 49164395 Air Filter Element | Donaldson FPG10 Spec

Ingersoll Rand 49164395 air filter element built to Donaldson FPG10 two-stage RadialSeal specification. 208 mm OD x 106 mm ID x 409 mm length, 99.9% filtration efficiency (ISO 5011), tangential pre-cleaner removes up to 85% of coarse dust. Tool-free installation, 2000-hour or 3-month service interval.

SKU
49164395
Contact Sales WhatsApp
  • Export packaging & documentation support
  • OEM / ODM customization available
  • Sample and bulk order workflow

Product Overview

49164395 is the intake air filter element used on Ingersoll Rand screw air compressors, manufactured to the Donaldson FPG10 specification.

FPG10 is a two-stage intake filtration system. Air first passes through an integrated tangential pre-cleaner: the tangential inlet spins the airflow at high speed, and centrifugal force drives coarse particles to the housing wall. Up to 85% of coarse dust is separated before reaching the main element and is discharged automatically through the Vacuator dust valve at the bottom of the housing. Pre-cleaned air then enters the main element, where cellulose filter media performs fine filtration. This structure matters most in dusty environments: the main element carries only fine-particle load, maintaining a longer service life under high dust conditions.

Sealing also differs from conventional air filters. FPG uses Donaldson RadialSeal technology: a one-piece molded polyurethane end cap seals radially against the housing outlet tube, eliminating the glued gasket of older axial elements. Fewer parts means fewer failure points, and gasket aging, detachment, and misalignment are eliminated. Installation and removal require no tools.

Key Specifications

ItemValue
Part Number49164395
Product NameAir Filter Element
BrandIngersoll Rand
Specification SourceDonaldson FPG10 (two-stage RadialSeal)
Role in AssemblyPrimary Element
Dimensions208 mm OD x 106 mm ID x 409 mm length
SealingRadialSeal (polyurethane end cap radial seal, no gasket)
Net WeightApprox. 1.88 kg
Filtration Efficiency99.9% (ISO 5011)
Pre-Cleaner EfficiencyUp to 85% of coarse dust removed
Rated Airflow≤346 cfm / 9.8 m³/min
Recommended Service Interval2000 hours or 3 months

Technical Parameters

Filtration Performance

ParameterValue / Note
Filtration Rating5 μm class (main element)
Filtration Efficiency99.9% (per ISO 5011)
Pre-Cleaner EfficiencyUp to 85% coarse dust removal (tangential pre-cleaner stage)
Filter ClassTwo-stage: centrifugal pre-cleaning + cellulose main element; not rated under EN 779 HVAC classification
Dust Holding CapacityApprox. 1200 g

In a single-stage filter, the media carries both coarse and fine particles, so coarse dust accumulates rapidly on the surface, pressure drop rises quickly, and service life is shortened. FPG10 transfers the coarse-dust load to the centrifugal pre-cleaner, significantly improving the load profile of the main element. This is why the design is widely used on construction machinery and generator sets operating in dusty conditions.

Flow and Pressure Drop

ParameterValue / Note
Rated Airflow≤346 cfm / 9.8 m³/min (filter assembly rated intake)
Filtration Face VelocityApprox. 0.038 m/s
Initial Pressure DropApprox. 0.5–1.0 kPa (approx. 50–100 mmH&sub2;O)
Operating Pressure DifferentialFrom new-element initial resistance to blockage alarm value
Alarm / Final ResistancePer the intake restriction indicator yellow/red zone
Pressure Drop vs. EnergyEach 1 kPa increase in intake resistance raises unit energy consumption by approx. 1%

Rising intake resistance reduces intake pressure and density. To maintain set discharge pressure and flow, the unit must do more work, and specific power increases. Based on a compression ratio calculation at 0.7 MPa discharge pressure and 101.3 kPa atmospheric pressure:

Intake ResistanceCompression RatioRelative Energy Increase
0 kPa (new element)7.91Baseline
2 kPa8.07+2.0%
4 kPa8.24+4.1%
6 kPa8.41+6.3%

As an element goes from new to severely blocked (0 → 6 kPa), unit energy consumption gradually rises by about 6%. This ongoing electricity cost typically far exceeds the price of one filter element. This is why the original FPG10 housing includes a restriction indicator port: replacement timing is determined by actual resistance, not by calendar estimates.

Dimensions and Installation

ParameterValue / Note
Dimensions208 mm OD x 106 mm ID x 409 mm length
ConfigurationPleated cylindrical element, two-stage RadialSeal primary element
Effective Filtration AreaApprox. 4.3 m²
Pleat CountApprox. 103 pleats
Pleat SpacingApprox. 4.8 mm
Mounting InterfaceRadial push-in; end cap seals against housing outlet tube
SealingRadialSeal; one-piece molded polyurethane end cap forms radial seal, no separate gasket
Companion ElementSafety element, mounted inside the primary element as backup protection

Procurement note: When cross-checking replacements, verify all three dimensions: 208 mm OD, 106 mm ID, and 409 mm length. The FPG design uses a radial seal; push the element in until the end cap contacts the outlet tube. Do not add a gasket—it will break the radial seal fit.

Materials

ParameterValue / Note
Filter MediaCellulose, per FPG10 specification
Media WeightApprox. 130 g/m²
Inner/Outer SupportGalvanized steel perforated support (inner cage + outer guard)
End CapsOne-piece molded polyurethane (PU), encapsulating media ends and sealing surface
SealRadialSeal formed by the polyurethane end cap body; no separate O-ring or gasket
BondingMolded integrally with end cap; no additional adhesive layer

Conventional axial elements consist of a metal end cap, glued gasket, and separate seal ring. Any one of these aging can cause bypass. FPG encapsulates the end cap, sealing surface, and media ends in a single polyurethane body, reducing part count and improving seal reliability—the basis for tool-free installation.

Operating Conditions

ParameterValue / Note
Operating TemperatureContinuous 83 °C
Relative Humidity≤80% RH, no condensation
Burst StrengthMedia burst strength approx. 200–400 kPa (per ISO 2758 paper burst test)
Collapse ResistanceElement withstands intake alarm differential without collapsing (RadialSeal layered support)
Special FunctionsTwo-stage filtration (integrated tangential pre-cleaner) + Vacuator automatic dust valve
HousingFPG housing is injection-molded plastic, corrosion-resistant, vibration-resistant

Service Life and Maintenance

ParameterValue / Note
Service Life2000 hours or 3 months, whichever comes first
High-Dust EnvironmentsFollow restriction indicator reading; schedule replacement when resistance enters yellow zone
Shelf LifeApprox. 2–3 years (unopened, dry, ventilated storage)

Standards

ItemContent
Product StandardISO 5011 (inlet air filters for internal combustion engines and compressors—performance testing); efficiency figures measured per this standard
Configuration StandardDonaldson FPG / FRG series filter specification (RadialSeal sealing system)
Commonly Cited Test StandardsISO 2941 / 2942 / 2943 / 3723 / 3724 / 3968
Standard Applicability NoteThe above ISO 29xx / 37xx series are general test methods for hydraulic fluid power filter elements. If a supplier can only provide hydraulic filter standards, request ISO 5011 or the original specification sheet.

Installation and Maintenance Steps

FPG design enables tool-free maintenance; a single service takes about 15 minutes.

  1. Shut down, verify zero pressure, lock out/tag out. Stop the unit, disconnect main power, and apply lockout/tagout. Criterion: controller shows system pressure at 0.

  2. Open the FPG filter service cover. Release the cover latches. FPG uses two spring latches or a twist-off cover; no tools required. Criterion: latches unbroken, cover undeformed.

  3. Remove the old element. Grip the polyurethane end cap and pull straight out. Criterion: note that the RadialSeal design has no gasket to peel. If a residual gasket is found on the housing outlet tube, a non-original part was previously installed; clean it off completely.

  4. Inspect the Vacuator dust valve. Check the rubber duckbill valve at the bottom of the housing. Criterion: valve opens and closes freely, no caked dust, no obstruction. This is the most commonly skipped step in FPG maintenance and the most consequential: a blocked dust valve disables the pre-cleaner stage, transferring the full dust load to the main element and sharply reducing service life.

  5. Check the pre-cleaner stage and housing for dust traces. Look for dust bypass tracks inside the housing and abnormal accumulation in the pre-cleaner swirl zone. Criterion: no dust tracks on inner walls; if tracks are present, inspect sealing surfaces.

  6. Install the new element. Push 49164395 into the housing until the polyurethane end cap contacts the outlet tube. Criterion: end cap seats fully against the outlet tube; no gasket is needed or permitted.

  7. Reinstall the service cover and check the restriction indicator. Refit the cover and secure latches. Confirm the intake restriction indicator is in the green zone; if resettable, press reset and verify it returns properly. Criterion: green zone reading, indicator operates normally.

  8. Start up and record. Start the unit, run to operating temperature, and read intake restriction. Criterion: resistance within new-element baseline range; record date, running hours, and resistance reading.

Installation rule: Do not start the unit before the element is fully seated. If the RadialSeal element is not pushed fully home, air bypasses directly through the gap between end cap and outlet tube, disabling both the pre-cleaner and main element—equivalent to running with no filter.

FAQ

What specification is 49164395?

A two-stage RadialSeal primary element built to Donaldson FPG10 specification. The integrated tangential pre-cleaner removes up to 85% of coarse dust first; the main element handles fine filtration.

Is it interchangeable with 49101637?

No. 49101637 is FPG09; dimensions and rated airflow differ from FPG10. To confirm: read the specification marking on the end cap of the currently installed element. If it reads FPG10, order this part; if FPG09, order 49101637.

Why does this element have no gasket?

Because it uses RadialSeal radial sealing. The polyurethane end cap body seals directly against the housing outlet tube, with no glued gasket or separate seal ring. Fewer parts, fewer failure points, and less chance of incorrect installation.

What does the Vacuator dust valve do?

It is the dust discharge port of the pre-cleaner stage. Coarse dust separated by the swirling airflow falls by gravity to the bottom of the housing and is discharged automatically through the Vacuator valve. If the valve becomes blocked, the pre-cleaner stage fails completely and all dust loads the main element. Check it at every element change—this is the key maintenance action for the FPG design.

How often should it be replaced?

Recommended interval is 2000 hours or 3 months, whichever comes first. More accurately, follow the intake restriction indicator: schedule replacement when resistance enters the yellow zone. In high-dust sites, replace earlier based on indicator readings.

Can the element be blown clean and reused?

No. This is a dry, disposable element. It must not be washed or reverse-blown with compressed air; reverse blowing damages the media fiber structure and creates invisible channels that let unfiltered air pass—more dangerous than not changing the filter.

Can a gasket be added to improve sealing?

No, and it is unnecessary. RadialSeal relies on radial compression of the end cap body. Adding a gasket lifts the element off the outlet tube and breaks the seal fit, causing bypass.

The restriction indicator never moves—is that normal?

No. A stuck indicator is a common failure point and can show a "clean" reading when the element is actually blocked. Press and check it returns properly at every service; if it has failed, replace the element on a conservative time interval until the indicator is repaired.

How does the FPG plastic housing compare with metal housings?

The FPG injection-molded housing is corrosion-resistant, lightweight, and vibration-resistant. It does not rust in coastal salt-spray or humid environments. The tool-free design also makes field maintenance faster. This is why the FPG series is widely used on construction machinery and mobile equipment.

How can I be 100% sure this is the right part?

Three steps: (1) Read the specification marking on the end cap of the currently installed element and confirm it is FPG10. (2) Measure the old element's OD and length to verify 208 mm and 409 mm. (3) If the old element has been discarded, provide the model marking on the filter housing and we will cross-check against FPG specifications.

Compatible Equipment

This element is supplied to Donaldson FPG10 specification and fits Ingersoll Rand screw air compressors equipped with the FPG10 air filter housing.

FPG10 is a Donaldson finished filter assembly specification used by multiple OEMs as a standard intake filtration unit. Identification points:

ItemSpecification
Filter AssemblyDonaldson FPG10 (element interchangeable with FRG10 series)
Rated Airflow≤346 cfm / 9.8 m³/min
Role in AssemblyPrimary Element
Other Specification in SeriesFPG09; part number 49101637, different dimensions and airflow, not interchangeable
Sealing SystemRadialSeal (polyurethane end cap radial seal)

How to Confirm Fit

  1. Preferred: Read the specification marking on the end cap of the currently installed element. FPG10 means this part fits; FPG09 means order 49101637.
  2. Alternative: Measure the old element's OD and length to verify 208 mm x 409 mm.
  3. Fallback: Provide the model marking on the filter housing or a photo of the unit nameplate; we will cross-check against FPG specifications.

Note on model coverage: Donaldson FPG10 is a general-purpose filter assembly used by several OEMs, so its fitment is not limited to one specific model list. The deciding factor is whether the filter assembly is FPG10, not the unit model itself. If the unit nameplate does not state the filter specification, confirm using any of the three steps above.

Related Components

The FPG10 air filter is a complete system. Beyond the primary element, seven components are maintained together with this part. Listed by component—function—inspection point:

ComponentFunctionInspection Point
Safety ElementBackup element inside the primary; protects downstream if the primary is damaged or during change intervalsGenerally replaced on the same interval or every other interval; check media for damage
Vacuator Dust ValveAutomatic dust discharge port of the pre-cleaner stage, expels centrifugally separated coarse dustCheck at every element change: valve must open/close freely, no caked dust, no obstruction
Restriction IndicatorIndicates element blockage; authoritative basis for replacement timingCheck needle returns properly; connecting line must be clear
Service Cover and LatchesTool-free opening structure of the FPG housingCheck latches for cracks, cover for deformation; no air leaks after securing
FPG Housing AssemblyInjection-molded plastic housing with tangential inlet and pre-cleaner swirl zoneCheck inner walls for dust bypass tracks; check plastic for cracks
Intake Hose and ClampsConnects filter housing to machine intakeCheck for cracks, aging, looseness; bypass leakage is as harmful as no filter
Other Primary Element in SeriesFPG09; part number 49101637Different dimensions and airflow, not interchangeable; distinguish when stocking

Companion replacement advice: The maintenance value of the FPG10 system centers on whether the pre-cleaner stage is working properly. When changing the primary element, inspect the Vacuator valve and restriction indicator at the same time. If either fails, primary element life is significantly shortened. Their cost is far lower than the primary element, yet they determine how long it lasts.